Roof Drain Pipe Design

Image Result For Residential Flat Roof Construction Detail Flat Roof Design Roof Drain Flat Roof

Image Result For Residential Flat Roof Construction Detail Flat Roof Design Roof Drain Flat Roof

Bircoprofil Birco Drainage Systems Flat Roof Roof House Designs Exterior

Bircoprofil Birco Drainage Systems Flat Roof Roof House Designs Exterior

Pin On Quirk

Pin On Quirk

Flat Roof Detail Without Parapet Flat Roof Roof Detail Parapet

Flat Roof Detail Without Parapet Flat Roof Roof Detail Parapet

Rain Chain Jpg 1 000 1 448 Pixels Rain Chain Roof Detail Gutters

Rain Chain Jpg 1 000 1 448 Pixels Rain Chain Roof Detail Gutters

Image Result For Corner Scupper Roof Drain Detail Roof Drain Roof Cement School Architecture

Image Result For Corner Scupper Roof Drain Detail Roof Drain Roof Cement School Architecture

Image Result For Corner Scupper Roof Drain Detail Roof Drain Roof Cement School Architecture

1 8 1 4 and 1 2 per foot.

Roof drain pipe design.

Enter table 1108 2 until you find a diameter pipe that will. Take the roof s total square footage and divide by the total square footage handled by one drain. 50 000 4 400 11 36. Different horizontal sloping will offer different drainage capacities.

According to the chart for 1 8 slope per 12 of pipe for 5 000 square feet of roof area with a 6 per hour of rainfall the required pipe size is 8. The result is the number of drains needed. We also stock many of the top selling drains and parts onsite so most orders ship same day. The roof drainage outlets and rainwater downpipes are calculated based on the design principles for gravity drainage systems established in ss525 2006 code of practice for drainage of roofs.

Cast iron roof drain with 2 in. Section 101 5 of the ipc tells us not to reduce the pipe size in the direction of flow. Or 12 drains required. A minimum 5 inch diameter drain on a 1 4 inch per foot slope is required.

Hy tech is an authorized distributor of all roof drain manufacturers so you can find what you need when you need it. A 5 inch diameter pipe with a 1 4 inch per foot slope will carry 4 720 sq ft. The flexible design easily bends and holds its shape and can be extended from 25 in. Code tables outline pipe slopes of.

Buried or underground roof drainage downspout defects clogging overflowing holes corrosion leaks that cause wet basements or crawl areas proper installation of buried downspout extensions proper installation of french drains seepage pits at flat sites gutter downspout defects cause wet basements crawl areas questions answers about installing maintaining repairing buried roof. But this isn t the whole story. Use this downspout extension to divert water away from the foundation or connect to drainage pipe and catch basin to control drainage. If you need help finding a drain ask our drain wizard or call to speak with our roof drain expert.

Horizontal drain 10 000 sq ft. Section 1105 roof drains 1105 2 roof drain flow rate. To convert to an area for use in table 1108 2 do this. Watts drainage products rd 300 r series 4 in.

Pipe sizing is listed as amount of square foot roof areas served by the drains. The flow rate used for sizing the storm drainage piping shall be based on the maximum anticipated ponding on the roof. This reveals that the minimum size for the leader pipe is 5. Rd rd 10 000 4 x 3 75 9 375 sq ft.

To size the vertical roof drain for the same parameters 5 000 square feet of room area and 6 per hour of rain consult table 1106 2 figure 3.

Is There Any Alternative To Roof Gutters Gutters Rain Water Collection Yard Drainage

Is There Any Alternative To Roof Gutters Gutters Rain Water Collection Yard Drainage

Flat Roof Drainage Systems Flat Roof Flat Roof Skylights Flat Roof Design

Flat Roof Drainage Systems Flat Roof Flat Roof Skylights Flat Roof Design

Vent Washing Machine Drain Washing Machines Plumbing Drains Diy Plumbing Plumbing Installation

Vent Washing Machine Drain Washing Machines Plumbing Drains Diy Plumbing Plumbing Installation

Roof Section

Roof Section

Source : pinterest.com