Never attach roof sheathing with staples.
Roof sheathing nails.
The typical thickness range for sheathing is 3 8 to 3 4 inch.
Technical fact sheet no.
If 8d common nails are specified the nail diameter must be at least 0 131 inch wider than typical 8d pneumatic nails.
18 roof sheathing installation home builder s guide to coastal construction page 2 of 3 recommended that deformed shank nails be used throughout the entire roof.
Nails from sheathing to ridge board roof sheathing ridge board ridge board joist or truss joist or truss roof sheathing vent holes on each side of ridge board.
1 1 4 roofing nails will be fine for installing the shingles.
There is a common misconception in the building industry that screws always outperform nails when attaching wood to wood.
At intermediate supports fasten panels 12 inches on center.
Sheathing should be a minimum of 19 32 inch thick.
You will want to borrow a framing nailer for this the rafters may be so hard that hand nailing could be problematic.
The cheapest and easiest is to re nail or better yet screw down the sheathing when you replace your roof covering.
Nails for roof sheathing first if you re in a high wind uplift zone and even if you re not if hurricanes really are a concern you should consider yourself in one you ll want to use a modified nailing schedule typically 6 along the edge and in the field using 8d ring shank nails.
The attachment of roof sheathing can be improved in one of two ways.
It s true that screws have a highly effective withdrawal resistance which makes them excellent fasteners for tasks such as avoiding squeaks in flooring assemblies resisting uplift forces that occur in roofs and holding deck ledgers tight to.
Fasten roof sheathing panels properly.
Note holes should not remove more than half of the sheathing section note.
For slats featuring face widths of 12 inches you will space three nails evenly apart about every 3 inches.
8d ring shank nails should be used instead.
Make sure you hit the rafters when nailing if you just nail into the skip sheathing the nails may will pop.
Fasten panels with a minimum of 8d common 0 131 inch by 2 1 2 inch nails spaced a maximum of 6 inches on center at supported panel ends and edges.
System november 19 2014 9 51pm 7.
In high wind areas more fasteners may be required.
Generally you ll need to place two nails at each location where it makes contact with a roof truss.
If roof sheathing is cut and removed to achieve an air slot continuity and diaphragm action are affected.
Can screws be used instead of nails for attaching wall sheathing to framing.